{"id":25935,"date":"2020-11-16T09:00:50","date_gmt":"2020-11-16T09:00:50","guid":{"rendered":"https:\/\/tecnologiaparalaindustria.com\/?p=25935"},"modified":"2025-07-22T12:17:34","modified_gmt":"2025-07-22T12:17:34","slug":"parametros-para-la-correcta-medicion-de-las-vibraciones-mecanicas-en-maquinas","status":"publish","type":"post","link":"https:\/\/tecnologiaparalaindustria.com\/it\/parametros-para-la-correcta-medicion-de-las-vibraciones-mecanicas-en-maquinas\/","title":{"rendered":"Parametri per la corretta misurazione delle vibrazioni meccaniche sulle macchine"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_83 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Indice dei contenuti<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Allinea l&#039;indice dei contenuti\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/tecnologiaparalaindustria.com\/it\/parametros-para-la-correcta-medicion-de-las-vibraciones-mecanicas-en-maquinas\/#Cuando_se_utiliza_la_medicion_de_la_aceleracion\" >Cuando se utiliza la medici\u00f3n de la aceleraci\u00f3n<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/tecnologiaparalaindustria.com\/it\/parametros-para-la-correcta-medicion-de-las-vibraciones-mecanicas-en-maquinas\/#Lo_que_nos_revele_la_fase\" >Lo que nos revele la fase<\/a><\/li><\/ul><\/nav><\/div>\n<p class=\"p1\">Puesto que la velocidad de vibraci\u00f3n est\u00e1 en relaci\u00f3n directa con la severidad de la vibraci\u00f3n, para la mayor\u00eda de los fines generales de medici\u00f3n de las vibraciones mec\u00e1nicas en m\u00e1quinas, este es el par\u00e1metro de medici\u00f3n preferido. En l\u00edneas generales, las vibraciones que acontecen en la gama de frecuencias comprendida entre 600 y 60.00 cpm se miden mejor utilizado la velocidad de vibraci\u00f3n.<\/p>\n<p class=\"p1\">En este art\u00edculo, hablamos de los siguientes par\u00e1metros:<\/p>\n<ul class=\"ul1\">\n<li class=\"li1\">Cuando se utiliza la medici\u00f3n de la velocidad,<\/li>\n<li class=\"li1\">Cuando se utiliza la medici\u00f3n del desplazamiento, y<\/li>\n<li class=\"li1\">Cuando se utiliza la medici\u00f3n de la aceleraci\u00f3n.<\/li>\n<\/ul>\n<p class=\"p1\">En condiciones de esfuerzos din\u00e1micos, el desplazamiento de por si puede ser un mejor indicador de la severidad de la situaci\u00f3n. Hemos hablado de los efecto de un doblado repetido en relaci\u00f3n con la rotura de un pedazo de chapa met\u00e1lica, pero la chapa met\u00e1lica que usamos no demostr\u00f3 muy bien una de las propiedades de los componente m\u00e1s r\u00edgido de una m\u00e1quina, es decir la tendencia a tomarse quebradizos, lo que significa una propensidad a romperse o partirse cuando se los somete a esfuerzos superiores a un cierto l\u00edmite<\/p>\n<div class=\"alert alert-warning\">Por ejemplo, consideremos una m\u00e1quina de rotaci\u00f3n lenta, como un tambor de izaje en uso en las minas, que tenga una rotaci\u00f3n de 60 rpm con vibraci\u00f3n de desplazamiento de 20 mils de cresta a cresta generada por desbalance del rotor. En t\u00e9rmino de velocidad de vibraci\u00f3n, 20 mils a 60 cpm representa solamente 0,0585 pulg\/seg, (cresta), lo que ser\u00eda considerado \u201cbueno\u201d para maquinarias en general, con poco motivo de preocupaci\u00f3n inmediata. Sin embargo, hay que considerar que el rodamiento de esta m\u00e1quina est\u00e1 sometido a una deflexi\u00f3n de 20 mils. En estas condiciones puede ocurrir una rotura debida a esfuerzo (desplazamiento) m\u00e1s bien que fatiga (velocidad).<\/div>\n<p class=\"p1\">Generalmente, es en las bajas frecuencias que el desplazamiento puede ser el mejor indicador de la severidad de la vibraci\u00f3n, t\u00edpicamente, en la gama de frecuencias por debajo de los 600 cpm.<\/p>\n<p>&nbsp;<\/p>\n<h3 class=\"p1\"><span class=\"ez-toc-section\" id=\"Cuando_se_utiliza_la_medicion_de_la_aceleracion\"><\/span><b>Cuando se utiliza la medici\u00f3n de la aceleraci\u00f3n<\/b><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p class=\"p1\">La aceleraci\u00f3n est\u00e1 estrechamente relacionada con la fuerza, y fuerzas relativamente significativas pueden presentarse a altas frecuencias, aunque el desplazamiento y la velocidad sean m\u00ednimas, Por ejemplo, diremos una vibraci\u00f3n medida de 1,5 mils a 6.000 cpm. Esto corresponde a una lectura de velocidad de 0,471 pulg.\/seg.(cresta), lo que puede ser considerado como \u201crudo\u201d para maquinarias en general.Esto equivale tambi\u00e9n a una lectura de aceleraci\u00f3n de 0,7 g.<\/p>\n<p class=\"p1\">A continuaci\u00f3n, consideremos una vibraci\u00f3n de 0,015 mils a una frecuencia de 600.00 cpm. Esta vibraci\u00f3n tambi\u00e9n corresponde a una lectura de velocidad de 0,47 pulg.\/seg. (cresta), pero con una lectura de aceleraci\u00f3n de 70 g. A 6.000 cpm la rotura puede producirse debido a fatiga (velocidad), pero a la frecuencia m\u00e1s elevada de 600.000 cpm la rotura ocurrir\u00e1 con toda probabilidad a causa de la fuerza aplicada (aceleraci\u00f3n).<\/p>\n<p class=\"p1\">La aplicaci\u00f3n de una fuerza excesiva puede tener como resultado una falla de la lubricaci\u00f3n, ocasionado la rotura de la superficie de soporte de los rodamientos. Por lo tanto, a altas frecuencias, es decir de 60.00 cpm y m\u00e1s, la aceleraci\u00f3n puede ser el mejor indicador de la severidad de la vibraci\u00f3n.<\/p>\n<p>&nbsp;<\/p>\n<h3 class=\"p1\"><span class=\"ez-toc-section\" id=\"Lo_que_nos_revele_la_fase\"><\/span><b>Lo que nos revele la fase<\/b><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p class=\"p1\">La medici\u00f3n de fase es esencial en el <a href=\"https:\/\/tecnologiaparalaindustria.com\/it\/3-casos-de-uso-del-analisis-de-vibraciones-para-detectar-problemas-en-las-maquinas\/\" target=\"_blank\" rel=\"noopener noreferrer\"><span class=\"s1\"><b>analisi delle vibrazioni<\/b><\/span><\/a> para diagnosticar problemas espec\u00edficos de las m\u00e1quinas. Mediciones comparativas de l\u00e1ser se usan como sigue:<\/p>\n<ul class=\"ul1\">\n<li class=\"li1\"><b>Balanceo. <\/b>La fase se usa para determinar el tipo de desbalance, est\u00e1tico o din\u00e1mico, y para calcular la cantidad y la ubicaci\u00f3n angular de los pesos de correcci\u00f3n. Se usa tambi\u00e9n para evaluar los efectos de temperatura, carga, etc.<\/li>\n<\/ul>\n<ul class=\"ul1\">\n<li class=\"li1\"><b>Falta de alineamiento. <\/b>Las mediciones comparativas de fase revelan el tipo de falta de alineamiento (angular o de descentramiento) y la ubicaci\u00f3n de defecto.<\/li>\n<\/ul>\n<ul class=\"ul1\">\n<li class=\"li1\"><b>Aflojamiento. <\/b>Se usa la fase para detectar la existencia de movimiento relativo de los componentes de las m\u00e1quinas causando por un enlechado de mala calidad, por cimentaciones rotas o resquebrajadas, etc.<\/li>\n<\/ul>\n<ul class=\"ul1\">\n<li class=\"li1\"><b>Estudios de modalidad. <\/b>Las lectura comparativas de fase pueden revelar formas de modalidad en todos los tipos de estructura para maquinaria.<\/li>\n<\/ul>\n<p class=\"p1\">Las informaciones relacionadas con la fases se obtienen por medio de luz estrobosc\u00f3pica accionada por una se\u00f1al de vibraci\u00f3n, de un captador de referencia de fase e, en algunos casos, de un osciloscopio.<\/p>\n<p class=\"p1\">Ya que est\u00e1s interesado en saber m\u00e1s sobre los par\u00e1metros\u00a0para la correcta\u00a0medici\u00f3n de las vibraciones mec\u00e1nicas en m\u00e1quinas, te invitamos a conocer un <a href=\"https:\/\/tecnologiaparalaindustria.com\/it\/ejemplo-de-aplicacion-del-analisis-de-vibraciones-en-bombas-y-ventiladores\/\" target=\"_blank\" rel=\"noopener noreferrer\"><span class=\"s1\"><b>esempio di applicazione dell'analisi delle vibrazioni su pompe e ventilatori<\/b><\/span><\/a>e per iscriversi a <a href=\"https:\/\/koi-3QNFFA4OII.marketingautomation.services\/net\/m?md=1hu2UUuQ0QrwApavxq%2BKeXOntDiuzdVO\" target=\"_blank\" rel=\"noopener noreferrer\"><span class=\"s1\"><b>la nostra newsletter<\/b><\/span><\/a>, una newsletter che fornisce contenuti tecnici sulle migliori soluzioni tecnologiche per impianti industriali, con particolare attenzione all'automazione e alla manutenzione.<\/p>","protected":false},"excerpt":{"rendered":"<p>Puesto que la velocidad de vibraci\u00f3n est\u00e1 en relaci\u00f3n directa con la severidad de la vibraci\u00f3n, para la mayor\u00eda de los fines generales de medici\u00f3n de las vibraciones mec\u00e1nicas en &hellip;<\/p>","protected":false},"author":2,"featured_media":25936,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"categories":[496],"tags":[],"class_list":["type-post","category-equipos-industriales","CTA-newsletter","CTA-tpi","entry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Par\u00e1metros\u00a0para la medici\u00f3n de las vibraciones mec\u00e1nicas en m\u00e1quinas<\/title>\n<meta name=\"description\" content=\"Para la mayor\u00eda de los fines generales de medici\u00f3n de las vibraciones mec\u00e1nicas en m\u00e1quinas, la velocidad es el par\u00e1metro de medici\u00f3n preferido.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/tecnologiaparalaindustria.com\/it\/parametros-para-la-correcta-medicion-de-las-vibraciones-mecanicas-en-maquinas\/\" \/>\n<meta property=\"og:locale\" content=\"it_IT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Par\u00e1metros\u00a0para la medici\u00f3n de las vibraciones mec\u00e1nicas en m\u00e1quinas\" \/>\n<meta property=\"og:description\" content=\"Para la mayor\u00eda de los fines generales de medici\u00f3n de las vibraciones mec\u00e1nicas en m\u00e1quinas, la velocidad es el par\u00e1metro de medici\u00f3n preferido.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/tecnologiaparalaindustria.com\/it\/parametros-para-la-correcta-medicion-de-las-vibraciones-mecanicas-en-maquinas\/\" \/>\n<meta property=\"og:site_name\" content=\"Tecnolog\u00eda para la Industria\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/tecnologiaparalaindustria\" \/>\n<meta property=\"article:published_time\" content=\"2020-11-16T09:00:50+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-07-22T12:17:34+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/tecnologiaparalaindustria.com\/wp-content\/uploads\/2020\/11\/Medicio\u0301n-de-las-vibraciones-meca\u0301nicas-en-ma\u0301quinas-jpg.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"628\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"REDACCI\u00d3N\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"REDACCI\u00d3N\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minuti\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/parametros-para-la-correcta-medicion-de-las-vibraciones-mecanicas-en-maquinas\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/parametros-para-la-correcta-medicion-de-las-vibraciones-mecanicas-en-maquinas\\\/\"},\"author\":{\"name\":\"REDACCI\u00d3N\",\"@id\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/#\\\/schema\\\/person\\\/d04140bd22bb08f9a61cd720e5fe5038\"},\"headline\":\"Par\u00e1metros\u00a0para la correcta\u00a0medici\u00f3n de las vibraciones mec\u00e1nicas en m\u00e1quinas\",\"datePublished\":\"2020-11-16T09:00:50+00:00\",\"dateModified\":\"2025-07-22T12:17:34+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/parametros-para-la-correcta-medicion-de-las-vibraciones-mecanicas-en-maquinas\\\/\"},\"wordCount\":855,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/parametros-para-la-correcta-medicion-de-las-vibraciones-mecanicas-en-maquinas\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/wp-content\\\/uploads\\\/2020\\\/11\\\/Medicio\u0301n-de-las-vibraciones-meca\u0301nicas-en-ma\u0301quinas-jpg.webp\",\"articleSection\":[\"Equipos Industriales\"],\"inLanguage\":\"it-IT\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/parametros-para-la-correcta-medicion-de-las-vibraciones-mecanicas-en-maquinas\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/parametros-para-la-correcta-medicion-de-las-vibraciones-mecanicas-en-maquinas\\\/\",\"url\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/parametros-para-la-correcta-medicion-de-las-vibraciones-mecanicas-en-maquinas\\\/\",\"name\":\"Par\u00e1metros\u00a0para la medici\u00f3n de las vibraciones mec\u00e1nicas en m\u00e1quinas\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/parametros-para-la-correcta-medicion-de-las-vibraciones-mecanicas-en-maquinas\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/parametros-para-la-correcta-medicion-de-las-vibraciones-mecanicas-en-maquinas\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/wp-content\\\/uploads\\\/2020\\\/11\\\/Medicio\u0301n-de-las-vibraciones-meca\u0301nicas-en-ma\u0301quinas-jpg.webp\",\"datePublished\":\"2020-11-16T09:00:50+00:00\",\"dateModified\":\"2025-07-22T12:17:34+00:00\",\"description\":\"Para la mayor\u00eda de los fines generales de medici\u00f3n de las vibraciones mec\u00e1nicas en m\u00e1quinas, la velocidad es el par\u00e1metro de medici\u00f3n preferido.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/parametros-para-la-correcta-medicion-de-las-vibraciones-mecanicas-en-maquinas\\\/#breadcrumb\"},\"inLanguage\":\"it-IT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/parametros-para-la-correcta-medicion-de-las-vibraciones-mecanicas-en-maquinas\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/parametros-para-la-correcta-medicion-de-las-vibraciones-mecanicas-en-maquinas\\\/#primaryimage\",\"url\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/wp-content\\\/uploads\\\/2020\\\/11\\\/Medicio\u0301n-de-las-vibraciones-meca\u0301nicas-en-ma\u0301quinas-jpg.webp\",\"contentUrl\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/wp-content\\\/uploads\\\/2020\\\/11\\\/Medicio\u0301n-de-las-vibraciones-meca\u0301nicas-en-ma\u0301quinas-jpg.webp\",\"width\":1200,\"height\":628,\"caption\":\"Medici\u00f3n de las vibraciones mec\u00e1nicas en m\u00e1quinas\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/parametros-para-la-correcta-medicion-de-las-vibraciones-mecanicas-en-maquinas\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Par\u00e1metros\u00a0para la correcta\u00a0medici\u00f3n de las vibraciones mec\u00e1nicas en m\u00e1quinas\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/#website\",\"url\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/\",\"name\":\"Tecnolog\u00eda para la Industria\",\"description\":\"Soluciones tecnol\u00f3gicas para plantas industriales\",\"publisher\":{\"@id\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"it-IT\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/#organization\",\"name\":\"TPI - Tecnolog\u00eda para la Industria\",\"url\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/wp-content\\\/uploads\\\/2020\\\/08\\\/cropped-LOGO-FONDO-BLANCO.png\",\"contentUrl\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/wp-content\\\/uploads\\\/2020\\\/08\\\/cropped-LOGO-FONDO-BLANCO.png\",\"width\":520,\"height\":289,\"caption\":\"TPI - Tecnolog\u00eda para la Industria\"},\"image\":{\"@id\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/tecnologiaparalaindustria\",\"https:\\\/\\\/www.instagram.com\\\/tecnologiaparalaindustria\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/#\\\/schema\\\/person\\\/d04140bd22bb08f9a61cd720e5fe5038\",\"name\":\"REDACCI\u00d3N\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/daafa31e3c3038855edc007ca2e41a7f1af1259b6b79b93359d6de82934c5943?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/daafa31e3c3038855edc007ca2e41a7f1af1259b6b79b93359d6de82934c5943?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/daafa31e3c3038855edc007ca2e41a7f1af1259b6b79b93359d6de82934c5943?s=96&d=mm&r=g\",\"caption\":\"REDACCI\u00d3N\"},\"sameAs\":[\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Par\u00e1metros\u00a0para la medici\u00f3n de las vibraciones mec\u00e1nicas en m\u00e1quinas","description":"Para la mayor\u00eda de los fines generales de medici\u00f3n de las vibraciones mec\u00e1nicas en m\u00e1quinas, la velocidad es el par\u00e1metro de medici\u00f3n preferido.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/tecnologiaparalaindustria.com\/it\/parametros-para-la-correcta-medicion-de-las-vibraciones-mecanicas-en-maquinas\/","og_locale":"it_IT","og_type":"article","og_title":"Par\u00e1metros\u00a0para la medici\u00f3n de las vibraciones mec\u00e1nicas en m\u00e1quinas","og_description":"Para la mayor\u00eda de los fines generales de medici\u00f3n de las vibraciones mec\u00e1nicas en m\u00e1quinas, la velocidad es el par\u00e1metro de medici\u00f3n preferido.","og_url":"https:\/\/tecnologiaparalaindustria.com\/it\/parametros-para-la-correcta-medicion-de-las-vibraciones-mecanicas-en-maquinas\/","og_site_name":"Tecnolog\u00eda para la Industria","article_publisher":"https:\/\/www.facebook.com\/tecnologiaparalaindustria","article_published_time":"2020-11-16T09:00:50+00:00","article_modified_time":"2025-07-22T12:17:34+00:00","og_image":[{"width":1200,"height":628,"url":"https:\/\/tecnologiaparalaindustria.com\/wp-content\/uploads\/2020\/11\/Medicio\u0301n-de-las-vibraciones-meca\u0301nicas-en-ma\u0301quinas-jpg.webp","type":"image\/jpeg"}],"author":"REDACCI\u00d3N","twitter_card":"summary_large_image","twitter_misc":{"Written by":"REDACCI\u00d3N","Est. reading time":"4 minuti"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/tecnologiaparalaindustria.com\/parametros-para-la-correcta-medicion-de-las-vibraciones-mecanicas-en-maquinas\/#article","isPartOf":{"@id":"https:\/\/tecnologiaparalaindustria.com\/parametros-para-la-correcta-medicion-de-las-vibraciones-mecanicas-en-maquinas\/"},"author":{"name":"REDACCI\u00d3N","@id":"https:\/\/tecnologiaparalaindustria.com\/#\/schema\/person\/d04140bd22bb08f9a61cd720e5fe5038"},"headline":"Par\u00e1metros\u00a0para la correcta\u00a0medici\u00f3n de las vibraciones mec\u00e1nicas en m\u00e1quinas","datePublished":"2020-11-16T09:00:50+00:00","dateModified":"2025-07-22T12:17:34+00:00","mainEntityOfPage":{"@id":"https:\/\/tecnologiaparalaindustria.com\/parametros-para-la-correcta-medicion-de-las-vibraciones-mecanicas-en-maquinas\/"},"wordCount":855,"commentCount":0,"publisher":{"@id":"https:\/\/tecnologiaparalaindustria.com\/#organization"},"image":{"@id":"https:\/\/tecnologiaparalaindustria.com\/parametros-para-la-correcta-medicion-de-las-vibraciones-mecanicas-en-maquinas\/#primaryimage"},"thumbnailUrl":"https:\/\/tecnologiaparalaindustria.com\/wp-content\/uploads\/2020\/11\/Medicio\u0301n-de-las-vibraciones-meca\u0301nicas-en-ma\u0301quinas-jpg.webp","articleSection":["Equipos Industriales"],"inLanguage":"it-IT","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/tecnologiaparalaindustria.com\/parametros-para-la-correcta-medicion-de-las-vibraciones-mecanicas-en-maquinas\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/tecnologiaparalaindustria.com\/parametros-para-la-correcta-medicion-de-las-vibraciones-mecanicas-en-maquinas\/","url":"https:\/\/tecnologiaparalaindustria.com\/parametros-para-la-correcta-medicion-de-las-vibraciones-mecanicas-en-maquinas\/","name":"Par\u00e1metros\u00a0para la medici\u00f3n de las vibraciones mec\u00e1nicas en m\u00e1quinas","isPartOf":{"@id":"https:\/\/tecnologiaparalaindustria.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/tecnologiaparalaindustria.com\/parametros-para-la-correcta-medicion-de-las-vibraciones-mecanicas-en-maquinas\/#primaryimage"},"image":{"@id":"https:\/\/tecnologiaparalaindustria.com\/parametros-para-la-correcta-medicion-de-las-vibraciones-mecanicas-en-maquinas\/#primaryimage"},"thumbnailUrl":"https:\/\/tecnologiaparalaindustria.com\/wp-content\/uploads\/2020\/11\/Medicio\u0301n-de-las-vibraciones-meca\u0301nicas-en-ma\u0301quinas-jpg.webp","datePublished":"2020-11-16T09:00:50+00:00","dateModified":"2025-07-22T12:17:34+00:00","description":"Para la mayor\u00eda de los fines generales de medici\u00f3n de las vibraciones mec\u00e1nicas en m\u00e1quinas, la velocidad es el par\u00e1metro de medici\u00f3n preferido.","breadcrumb":{"@id":"https:\/\/tecnologiaparalaindustria.com\/parametros-para-la-correcta-medicion-de-las-vibraciones-mecanicas-en-maquinas\/#breadcrumb"},"inLanguage":"it-IT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/tecnologiaparalaindustria.com\/parametros-para-la-correcta-medicion-de-las-vibraciones-mecanicas-en-maquinas\/"]}]},{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/tecnologiaparalaindustria.com\/parametros-para-la-correcta-medicion-de-las-vibraciones-mecanicas-en-maquinas\/#primaryimage","url":"https:\/\/tecnologiaparalaindustria.com\/wp-content\/uploads\/2020\/11\/Medicio\u0301n-de-las-vibraciones-meca\u0301nicas-en-ma\u0301quinas-jpg.webp","contentUrl":"https:\/\/tecnologiaparalaindustria.com\/wp-content\/uploads\/2020\/11\/Medicio\u0301n-de-las-vibraciones-meca\u0301nicas-en-ma\u0301quinas-jpg.webp","width":1200,"height":628,"caption":"Medici\u00f3n de las vibraciones mec\u00e1nicas en m\u00e1quinas"},{"@type":"BreadcrumbList","@id":"https:\/\/tecnologiaparalaindustria.com\/parametros-para-la-correcta-medicion-de-las-vibraciones-mecanicas-en-maquinas\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/tecnologiaparalaindustria.com\/"},{"@type":"ListItem","position":2,"name":"Par\u00e1metros\u00a0para la correcta\u00a0medici\u00f3n de las vibraciones mec\u00e1nicas en m\u00e1quinas"}]},{"@type":"WebSite","@id":"https:\/\/tecnologiaparalaindustria.com\/#website","url":"https:\/\/tecnologiaparalaindustria.com\/","name":"Tecnologia per l'industria","description":"Soluzioni tecnologiche per impianti industriali","publisher":{"@id":"https:\/\/tecnologiaparalaindustria.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/tecnologiaparalaindustria.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"it-IT"},{"@type":"Organization","@id":"https:\/\/tecnologiaparalaindustria.com\/#organization","name":"TPI - Tecnologia per l'industria","url":"https:\/\/tecnologiaparalaindustria.com\/","logo":{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/tecnologiaparalaindustria.com\/#\/schema\/logo\/image\/","url":"https:\/\/tecnologiaparalaindustria.com\/wp-content\/uploads\/2020\/08\/cropped-LOGO-FONDO-BLANCO.png","contentUrl":"https:\/\/tecnologiaparalaindustria.com\/wp-content\/uploads\/2020\/08\/cropped-LOGO-FONDO-BLANCO.png","width":520,"height":289,"caption":"TPI - Tecnolog\u00eda para la Industria"},"image":{"@id":"https:\/\/tecnologiaparalaindustria.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/tecnologiaparalaindustria","https:\/\/www.instagram.com\/tecnologiaparalaindustria\/"]},{"@type":"Person","@id":"https:\/\/tecnologiaparalaindustria.com\/#\/schema\/person\/d04140bd22bb08f9a61cd720e5fe5038","name":"EDITORIALE","image":{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/secure.gravatar.com\/avatar\/daafa31e3c3038855edc007ca2e41a7f1af1259b6b79b93359d6de82934c5943?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/daafa31e3c3038855edc007ca2e41a7f1af1259b6b79b93359d6de82934c5943?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/daafa31e3c3038855edc007ca2e41a7f1af1259b6b79b93359d6de82934c5943?s=96&d=mm&r=g","caption":"REDACCI\u00d3N"},"sameAs":["https:\/\/tecnologiaparalaindustria.com\/"]}]}},"featured_image_src":"https:\/\/tecnologiaparalaindustria.com\/wp-content\/uploads\/2020\/11\/Medicio\u0301n-de-las-vibraciones-meca\u0301nicas-en-ma\u0301quinas-600x400.webp","featured_image_src_square":"https:\/\/tecnologiaparalaindustria.com\/wp-content\/uploads\/2020\/11\/Medicio\u0301n-de-las-vibraciones-meca\u0301nicas-en-ma\u0301quinas-600x600.webp","author_info":{"display_name":"REDACCI\u00d3N","author_link":"https:\/\/tecnologiaparalaindustria.com\/it\/author\/tecnologiavao\/"},"acf":[],"_links":{"self":[{"href":"https:\/\/tecnologiaparalaindustria.com\/it\/wp-json\/wp\/v2\/posts\/25935","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tecnologiaparalaindustria.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/tecnologiaparalaindustria.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/tecnologiaparalaindustria.com\/it\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/tecnologiaparalaindustria.com\/it\/wp-json\/wp\/v2\/comments?post=25935"}],"version-history":[{"count":0,"href":"https:\/\/tecnologiaparalaindustria.com\/it\/wp-json\/wp\/v2\/posts\/25935\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tecnologiaparalaindustria.com\/it\/wp-json\/wp\/v2\/media\/25936"}],"wp:attachment":[{"href":"https:\/\/tecnologiaparalaindustria.com\/it\/wp-json\/wp\/v2\/media?parent=25935"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/tecnologiaparalaindustria.com\/it\/wp-json\/wp\/v2\/categories?post=25935"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/tecnologiaparalaindustria.com\/it\/wp-json\/wp\/v2\/tags?post=25935"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}