{"id":1523,"date":"2018-06-13T09:00:23","date_gmt":"2018-06-13T09:00:23","guid":{"rendered":"https:\/\/tecnologiaparalaindustria.com\/?p=1523"},"modified":"2025-07-22T11:58:27","modified_gmt":"2025-07-22T11:58:27","slug":"monitorizacion-del-sellado-de-bombas-y-depositos-2","status":"publish","type":"post","link":"https:\/\/tecnologiaparalaindustria.com\/pt\/monitorizacion-del-sellado-de-bombas-y-depositos-2\/","title":{"rendered":"Controlo da estanquidade de bombas e reservat\u00f3rios"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_83 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">\u00cdndice<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Alternar \u00cdndice\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Alternar<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/tecnologiaparalaindustria.com\/pt\/monitorizacion-del-sellado-de-bombas-y-depositos-2\/#Variables_que_se_pueden_vigilar_con_el_sistema_de_monitorizacion_del_sellado_para_bombas_y_depositos\" >Vari\u00e1veis que podem ser monitorizadas com o sistema de monitoriza\u00e7\u00e3o de vedantes para bombas e dep\u00f3sitos:<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/tecnologiaparalaindustria.com\/pt\/monitorizacion-del-sellado-de-bombas-y-depositos-2\/#Funcionamiento_de_un_sistema_de_monitorizacion_del_sellado_para_bombas_y_depositos\" >Funcionamento de um sistema de monitoriza\u00e7\u00e3o de vedantes para bombas e reservat\u00f3rios:<\/a><\/li><\/ul><\/nav><\/div>\n<p><em><span style=\"font-weight: 400;\">A monitoriza\u00e7\u00e3o cont\u00ednua da veda\u00e7\u00e3o da bomba desempenha um papel fundamental no sector industrial, uma vez que estes sistemas permitem a calibra\u00e7\u00e3o, a configura\u00e7\u00e3o remota e o diagn\u00f3stico da bomba em tempo real, proporcionando a facilidade de um programa de manuten\u00e7\u00e3o.<\/span><\/em><\/p>\n<p>&nbsp;<\/p>\n<p><span style=\"font-weight: 400;\">Normalmente, uma pequena percentagem de bombas numa instala\u00e7\u00e3o de processo t\u00edpica \u00e9 monitorizada remotamente em linha, normalmente inspeccionada periodicamente por t\u00e9cnicos de opera\u00e7\u00f5es ou pessoal de manuten\u00e7\u00e3o em rondas no terreno, o que se torna uma fraqueza no processo porque aumenta o risco de falhas n\u00e3o planeadas, fugas, inc\u00eandios e outras situa\u00e7\u00f5es potencialmente perigosas.<\/span><\/p>\n<blockquote><p><span style=\"font-weight: 400;\">A ideia principal deste documento \u00e9 mostrar o funcionamento de um <\/span><i><span style=\"font-weight: 400;\">controlo da estanquidade das bombas e dos reservat\u00f3rios<\/span><\/i><span style=\"font-weight: 400;\"> e a sua import\u00e2ncia no \u00e2mbito da <\/span><a href=\"https:\/\/tecnologiaparalaindustria.com\/pt\/sistemas-para-gestionar-el-mantenimiento-preventivo-industrial\/\" target=\"_blank\" rel=\"noopener noreferrer\"><span style=\"font-weight: 400;\">gest\u00e3o da manuten\u00e7\u00e3o preventiva industrial<\/span><\/a><span style=\"font-weight: 400;\">como uma forma inovadora de melhorar a fiabilidade da bomba. <\/span><\/p><\/blockquote>\n<p><span style=\"font-weight: 400;\">Gra\u00e7as \u00e0 implementa\u00e7\u00e3o de um sistema de monitoriza\u00e7\u00e3o da veda\u00e7\u00e3o da bomba e do dep\u00f3sito, \u00e9 poss\u00edvel: <\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Reduzir ao m\u00ednimo as inspec\u00e7\u00f5es peri\u00f3dicas e manuais das instala\u00e7\u00f5es.<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Melhorar o desempenho dos vedantes da bomba.<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Evite repara\u00e7\u00f5es dispendiosas, risco de ferimentos e impacto ambiental.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">As bombas t\u00eam veda\u00e7\u00f5es auxiliares que devem ser lubrificadas atrav\u00e9s do sistema de descarga e esse fluido lubrificante tem um n\u00edvel que deve ser medido, mas, na maioria das vezes, a medi\u00e7\u00e3o on-line \u00e9 bastante limitada. Com o uso do monitoramento do n\u00edvel do reservat\u00f3rio, o usu\u00e1rio pode identificar quando reabastecer e onde descarregar o lubrificante para que ele n\u00e3o contamine o fluido do processo.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Assim, o sistema de descarga para lubrifica\u00e7\u00e3o dos selos auxiliares das bombas pode ser pressurizado ou despressurizado, ou seja, um selo n\u00e3o pressurizado. E s\u00e3o efetivamente concebidos para filtrar o fluido do processo sem serem contaminados com o lubrificante do vedante, mais conhecido como \"fluido tamp\u00e3o\"; mas acontece que, quando n\u00e3o h\u00e1 press\u00e3o nos vedantes, o fluido vaza para o ambiente, causando impactos ambientais e eventos indesejados. A n\u00e3o ser que se utilizem selos mec\u00e2nicos duplos pressurizados que evitem esta potencial fuga de fluido do processo para o ambiente.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Esta situa\u00e7\u00e3o pode ser evitada com um <\/span><a href=\"https:\/\/tecnologiaparalaindustria.com\/pt\/impacto-de-los-sistemas-de-alineacion-de-maquinas-rotativas-en-terminos-de-ahorro-y-retorno-de-la-inversion-para-plantas-industriales\/\" target=\"_blank\" rel=\"noopener noreferrer\"><span style=\"font-weight: 400;\">sistema de monitoriza\u00e7\u00e3o de vedantes para bombas ONLINE<\/span><\/a><span style=\"font-weight: 400;\">porque tamb\u00e9m monitoriza a taxa de varia\u00e7\u00e3o do n\u00edvel de medi\u00e7\u00e3o do caudal nos vedantes para alertar as opera\u00e7\u00f5es ou a manuten\u00e7\u00e3o quando o fluido se esgota mais rapidamente do que o normal. Isto permite que as opera\u00e7\u00f5es tenham mais tempo para mudar para a bomba de reserva, p\u00f4-la a funcionar e alertar o pessoal de manuten\u00e7\u00e3o.<\/span><\/p>\n<blockquote><p><span style=\"font-weight: 400;\">A <\/span><span style=\"font-weight: 400;\">sistema de monitoriza\u00e7\u00e3o em linha da estanquidade da bomba <\/span><span style=\"font-weight: 400;\">tamb\u00e9m serve para monitorizar a taxa de varia\u00e7\u00e3o do n\u00edvel de medi\u00e7\u00e3o do caudal nos vedantes para alertar os t\u00e9cnicos de opera\u00e7\u00f5es ou de manuten\u00e7\u00e3o quando o fluido se esgota mais depressa do que o normal. Isto permite que os t\u00e9cnicos de opera\u00e7\u00f5es tenham mais tempo para mudar para a bomba de reserva, p\u00f4-la a funcionar e alertar o pessoal de manuten\u00e7\u00e3o.<\/span><\/p><\/blockquote>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-1524 size-full\" title=\"Monitoriza\u00e7\u00e3o da veda\u00e7\u00e3o da bomba\" src=\"https:\/\/tecnologiaparalaindustria.com\/wp-content\/uploads\/2018\/06\/Monitorizacion-del-sellado-de-bombas.png\" alt=\"Monitoriza\u00e7\u00e3o da veda\u00e7\u00e3o da bomba\" width=\"1200\" height=\"628\" srcset=\"https:\/\/tecnologiaparalaindustria.com\/wp-content\/uploads\/2018\/06\/Monitorizacion-del-sellado-de-bombas-18x9.png 18w, https:\/\/tecnologiaparalaindustria.com\/wp-content\/uploads\/2018\/06\/Monitorizacion-del-sellado-de-bombas-150x79.png 150w, https:\/\/tecnologiaparalaindustria.com\/wp-content\/uploads\/2018\/06\/Monitorizacion-del-sellado-de-bombas-300x157.png 300w, https:\/\/tecnologiaparalaindustria.com\/wp-content\/uploads\/2018\/06\/Monitorizacion-del-sellado-de-bombas-390x205.png 390w, https:\/\/tecnologiaparalaindustria.com\/wp-content\/uploads\/2018\/06\/Monitorizacion-del-sellado-de-bombas-768x402.png 768w, https:\/\/tecnologiaparalaindustria.com\/wp-content\/uploads\/2018\/06\/Monitorizacion-del-sellado-de-bombas-1024x536.png 1024w, https:\/\/tecnologiaparalaindustria.com\/wp-content\/uploads\/2018\/06\/Monitorizacion-del-sellado-de-bombas.png 1200w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><\/p>\n<p><span style=\"font-weight: 400;\">Isto n\u00e3o \u00e9 poss\u00edvel se se mantiver a abordagem tradicional de verifica\u00e7\u00f5es manuais mensais no terreno com a utiliza\u00e7\u00e3o de interruptores para detetar n\u00edveis baixos, press\u00f5es elevadas ou temperaturas elevadas. \u00c9 por isso que a norma API (American Petroleum Institute) 682 especifica os requisitos e recomenda a utiliza\u00e7\u00e3o de <\/span><a href=\"https:\/\/tecnologiaparalaindustria.com\/pt\/las-tecnologias-de-alineacion-de-maquinas-rotativas-disminuyen-hasta-un-10-los-costes-energeticos\/\" target=\"_blank\" rel=\"noopener noreferrer\"><span style=\"font-weight: 400;\">monitoriza\u00e7\u00e3o de vedantes para bombas centr\u00edfugas e rotativas<\/span><\/a> <span style=\"font-weight: 400;\">utilizados nos sectores do petr\u00f3leo, do g\u00e1s natural e dos produtos qu\u00edmicos.<\/span><\/p>\n<blockquote><p><span style=\"font-weight: 400;\">Um interrutor mec\u00e2nico tradicional n\u00e3o \u00e9 t\u00e3o eficaz como um transmissor porque s\u00f3 pode fornecer um sinal de ligar\/desligar. Ao contr\u00e1rio de um transmissor, um interrutor n\u00e3o pode indicar a dist\u00e2ncia de um alarme ou ponto de ajuste, pelo que n\u00e3o pode ser utilizado para prever problemas. <\/span><\/p><\/blockquote>\n<p><span style=\"font-weight: 400;\">Os transmissores inteligentes permitem a calibra\u00e7\u00e3o, a configura\u00e7\u00e3o remota e o diagn\u00f3stico, proporcionando valor adicional e facilidade de manuten\u00e7\u00e3o. A medi\u00e7\u00e3o correcta e atempada da press\u00e3o pode evitar a degrada\u00e7\u00e3o precoce do vedante e problemas mais graves de avaria da bomba.<\/span><\/p>\n<p>&nbsp;<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Variables_que_se_pueden_vigilar_con_el_sistema_de_monitorizacion_del_sellado_para_bombas_y_depositos\"><\/span><strong>Vari\u00e1veis que podem ser monitorizadas com o sistema de monitoriza\u00e7\u00e3o de vedantes para bombas e dep\u00f3sitos:<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p><span style=\"font-weight: 400;\">Geralmente, as grandes bombas em condutas s\u00e3o monitorizadas com sensores para controlar diferentes vari\u00e1veis, entre as quais as seguintes:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Press\u00e3o de entrada da bomba.<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">N\u00edvel de consumo da bomba (do tubo de alimenta\u00e7\u00e3o do reservat\u00f3rio).<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Press\u00e3o de descarga da bomba.<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Press\u00e3o diferencial da bomba entre a entrada e a descarga.<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Temperatura do motor da bomba.<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Temperatura da bomba.<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Vibra\u00e7\u00e3o da bomba.<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">N\u00edvel do reservat\u00f3rio do sistema de veda\u00e7\u00e3o da bomba.<\/span><\/li>\n<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Press\u00e3o de ventila\u00e7\u00e3o do vapor.<\/span><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Funcionamiento_de_un_sistema_de_monitorizacion_del_sellado_para_bombas_y_depositos\"><\/span><strong>Funcionamento de um sistema de monitoriza\u00e7\u00e3o de vedantes para bombas e reservat\u00f3rios:<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p><span style=\"font-weight: 400;\">Este \u00e9 um medidor de n\u00edvel como elemento principal que permite ver as gotas do produto dentro da coluna de fluido. O man\u00f3metro est\u00e1 localizado acima do produto e afastado do percurso do fluxo. Isto evita que entre em contacto com o produto e o contamine. <\/span><\/p>\n<p><span style=\"font-weight: 400;\">Inclui um interrutor, que est\u00e1 posicionado para reagir imediatamente antes de o recipiente de conten\u00e7\u00e3o transbordar, detectando a tempo qualquer contamina\u00e7\u00e3o inesperada do fluido lubrificante entre os vedantes. Os monitores de veda\u00e7\u00e3o de bombas podem funcionar numa variedade de ambientes, especialmente na ind\u00fastria petroqu\u00edmica.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">No caso de bombas instaladas em po\u00e7os de petr\u00f3leo, o medidor de n\u00edvel \u00e9 capaz de detetar se h\u00e1 mistura do fluido do reservat\u00f3rio com o lubrificante do selo, evitando assim a contamina\u00e7\u00e3o do produto.  Neste cen\u00e1rio, s\u00e3o utilizados transmissores de radar de ondas guiadas sem fios que proporcionam uma medi\u00e7\u00e3o mais exacta do dep\u00f3sito de lavagem do vedante do que o n\u00edvel hidrost\u00e1tico.<\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-1525 size-full\" title=\"Monitoriza\u00e7\u00e3o da veda\u00e7\u00e3o da bomba\" src=\"https:\/\/tecnologiaparalaindustria.com\/wp-content\/uploads\/2018\/06\/Monitorizacion-del-sellado-de-bombas-2.png\" alt=\"Monitoriza\u00e7\u00e3o da veda\u00e7\u00e3o da bomba\" width=\"1200\" height=\"628\" srcset=\"https:\/\/tecnologiaparalaindustria.com\/wp-content\/uploads\/2018\/06\/Monitorizacion-del-sellado-de-bombas-2-18x9.png 18w, https:\/\/tecnologiaparalaindustria.com\/wp-content\/uploads\/2018\/06\/Monitorizacion-del-sellado-de-bombas-2-150x79.png 150w, https:\/\/tecnologiaparalaindustria.com\/wp-content\/uploads\/2018\/06\/Monitorizacion-del-sellado-de-bombas-2-300x157.png 300w, https:\/\/tecnologiaparalaindustria.com\/wp-content\/uploads\/2018\/06\/Monitorizacion-del-sellado-de-bombas-2-390x205.png 390w, https:\/\/tecnologiaparalaindustria.com\/wp-content\/uploads\/2018\/06\/Monitorizacion-del-sellado-de-bombas-2-768x402.png 768w, https:\/\/tecnologiaparalaindustria.com\/wp-content\/uploads\/2018\/06\/Monitorizacion-del-sellado-de-bombas-2-1024x536.png 1024w, https:\/\/tecnologiaparalaindustria.com\/wp-content\/uploads\/2018\/06\/Monitorizacion-del-sellado-de-bombas-2.png 1200w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><\/p>\n<p><span style=\"font-weight: 400;\">Com indicadores de transmissores, instrumentos com fios ou sensores sem fios, o pessoal no terreno pode monitorizar visualmente os par\u00e2metros de funcionamento do equipamento e os operadores podem ver os mesmos dados numa sala de controlo, o que faz com que seja uma forma segura de monitoriza\u00e7\u00e3o de vedantes para bombas e tanques.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">\u00c9 tamb\u00e9m uma forma de analisar os dados obtidos a partir de transmissores para prever problemas antes que eles ocorram; esta previs\u00e3o de falhas permite que a manuten\u00e7\u00e3o ocorra antes de uma falha.<\/span><\/p>\n<p>&nbsp;<\/p>\n<p><span style=\"font-weight: 400;\">Se pretender obter mais informa\u00e7\u00f5es sobre as novas tecnologias de controlo e gest\u00e3o de processos, convido-o a subscrever a <\/span><a href=\"https:\/\/tecnologiaparalaindustria.com\/pt\/newsletter\/?utm_source=Newsletter&amp;utm_medium=Cta_web&amp;utm_campaign=Newsletter_cta_web\" target=\"_blank\" rel=\"noopener noreferrer\"><span style=\"font-weight: 400;\">Boletim informativo sobre tecnologia para a ind\u00fastria<\/span><\/a><span style=\"font-weight: 400;\">onde pode obter mais informa\u00e7\u00f5es sobre os sistemas de monitoriza\u00e7\u00e3o da estanquidade das bombas, bem como documentar as vantagens da instala\u00e7\u00e3o destes sistemas.<\/span><\/p>\n<p><a href=\"https:\/\/recursos.tecnologiaparalaindustria.com\/newsletter?utm_source=Newsletter&amp;utm_medium=Cta_web&amp;utm_campaign=Newsletter_cta_web\" target=\"_blank\" rel=\"noopener noreferrer\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-2307 size-full\" src=\"https:\/\/tecnologiaparalaindustria.com\/wp-content\/uploads\/2019\/03\/CTA.NEWSLETTER-TECNOLOGIA-PARA-LA-INDUSTRIA.png\" alt=\"tecnologia de boletins informativos para a ind\u00fastria - Aumentar a efici\u00eancia das m\u00e1quinas\" width=\"2400\" height=\"1200\" srcset=\"https:\/\/tecnologiaparalaindustria.com\/wp-content\/uploads\/2019\/03\/CTA.NEWSLETTER-TECNOLOGIA-PARA-LA-INDUSTRIA-18x9.png 18w, https:\/\/tecnologiaparalaindustria.com\/wp-content\/uploads\/2019\/03\/CTA.NEWSLETTER-TECNOLOGIA-PARA-LA-INDUSTRIA-150x75.png 150w, https:\/\/tecnologiaparalaindustria.com\/wp-content\/uploads\/2019\/03\/CTA.NEWSLETTER-TECNOLOGIA-PARA-LA-INDUSTRIA-300x150.png 300w, https:\/\/tecnologiaparalaindustria.com\/wp-content\/uploads\/2019\/03\/CTA.NEWSLETTER-TECNOLOGIA-PARA-LA-INDUSTRIA-390x195.png 390w, https:\/\/tecnologiaparalaindustria.com\/wp-content\/uploads\/2019\/03\/CTA.NEWSLETTER-TECNOLOGIA-PARA-LA-INDUSTRIA-768x384.png 768w, https:\/\/tecnologiaparalaindustria.com\/wp-content\/uploads\/2019\/03\/CTA.NEWSLETTER-TECNOLOGIA-PARA-LA-INDUSTRIA-1024x512.png 1024w, https:\/\/tecnologiaparalaindustria.com\/wp-content\/uploads\/2019\/03\/CTA.NEWSLETTER-TECNOLOGIA-PARA-LA-INDUSTRIA-1536x768.png 1536w, https:\/\/tecnologiaparalaindustria.com\/wp-content\/uploads\/2019\/03\/CTA.NEWSLETTER-TECNOLOGIA-PARA-LA-INDUSTRIA-2048x1024.png 2048w, https:\/\/tecnologiaparalaindustria.com\/wp-content\/uploads\/2019\/03\/CTA.NEWSLETTER-TECNOLOGIA-PARA-LA-INDUSTRIA.png 2400w\" sizes=\"auto, (max-width: 2400px) 100vw, 2400px\" \/><\/a><\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>A monitoriza\u00e7\u00e3o cont\u00ednua dos vedantes da bomba desempenha um papel fundamental no sector industrial, uma vez que estes sistemas permitem a calibra\u00e7\u00e3o, a configura\u00e7\u00e3o remota e o diagn\u00f3stico dos vedantes da bomba, bem como a ...<\/p>","protected":false},"author":2,"featured_media":1529,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"categories":[472],"tags":[95],"class_list":["type-post","category-automatizacion-y-control","tag-articulos","entry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Monitorizaci\u00f3n del sellado de bombas y dep\u00f3sitos<\/title>\n<meta name=\"description\" content=\"La monitorizaci\u00f3n del sellado de bombas vigila la tasa de cambio en el nivel de medida del flujo de los sellos de la bomba para alertar mantenimiento.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/tecnologiaparalaindustria.com\/pt\/monitorizacion-del-sellado-de-bombas-y-depositos-2\/\" \/>\n<meta property=\"og:locale\" content=\"pt_PT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Monitorizaci\u00f3n del sellado de bombas y dep\u00f3sitos\" \/>\n<meta property=\"og:description\" content=\"La monitorizaci\u00f3n del sellado de bombas vigila la tasa de cambio en el nivel de medida del flujo de los sellos de la bomba para alertar mantenimiento.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/tecnologiaparalaindustria.com\/pt\/monitorizacion-del-sellado-de-bombas-y-depositos-2\/\" \/>\n<meta property=\"og:site_name\" content=\"Tecnolog\u00eda para la Industria\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/tecnologiaparalaindustria\" \/>\n<meta property=\"article:published_time\" content=\"2018-06-13T09:00:23+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-07-22T11:58:27+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/tecnologiaparalaindustria.com\/wp-content\/uploads\/2018\/06\/Monitorizacion-del-sellado-de-bombas-2-jpg.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"300\" \/>\n\t<meta property=\"og:image:height\" content=\"208\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"REDACCI\u00d3N\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"REDACCI\u00d3N\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tempo estimado de leitura\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/monitorizacion-del-sellado-de-bombas-y-depositos-2\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/monitorizacion-del-sellado-de-bombas-y-depositos-2\\\/\"},\"author\":{\"name\":\"REDACCI\u00d3N\",\"@id\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/#\\\/schema\\\/person\\\/d04140bd22bb08f9a61cd720e5fe5038\"},\"headline\":\"Monitorizaci\u00f3n del sellado de bombas y dep\u00f3sitos\",\"datePublished\":\"2018-06-13T09:00:23+00:00\",\"dateModified\":\"2025-07-22T11:58:27+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/monitorizacion-del-sellado-de-bombas-y-depositos-2\\\/\"},\"wordCount\":1206,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/monitorizacion-del-sellado-de-bombas-y-depositos-2\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/wp-content\\\/uploads\\\/2018\\\/06\\\/Monitorizacion-del-sellado-de-bombas-2-jpg.webp\",\"keywords\":[\"Art\u00edculos\"],\"articleSection\":[\"Automatizaci\u00f3n y control\"],\"inLanguage\":\"pt-PT\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/monitorizacion-del-sellado-de-bombas-y-depositos-2\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/monitorizacion-del-sellado-de-bombas-y-depositos-2\\\/\",\"url\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/monitorizacion-del-sellado-de-bombas-y-depositos-2\\\/\",\"name\":\"Monitorizaci\u00f3n del sellado de bombas y dep\u00f3sitos\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/monitorizacion-del-sellado-de-bombas-y-depositos-2\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/monitorizacion-del-sellado-de-bombas-y-depositos-2\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/wp-content\\\/uploads\\\/2018\\\/06\\\/Monitorizacion-del-sellado-de-bombas-2-jpg.webp\",\"datePublished\":\"2018-06-13T09:00:23+00:00\",\"dateModified\":\"2025-07-22T11:58:27+00:00\",\"description\":\"La monitorizaci\u00f3n del sellado de bombas vigila la tasa de cambio en el nivel de medida del flujo de los sellos de la bomba para alertar mantenimiento.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/monitorizacion-del-sellado-de-bombas-y-depositos-2\\\/#breadcrumb\"},\"inLanguage\":\"pt-PT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/monitorizacion-del-sellado-de-bombas-y-depositos-2\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-PT\",\"@id\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/monitorizacion-del-sellado-de-bombas-y-depositos-2\\\/#primaryimage\",\"url\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/wp-content\\\/uploads\\\/2018\\\/06\\\/Monitorizacion-del-sellado-de-bombas-2-jpg.webp\",\"contentUrl\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/wp-content\\\/uploads\\\/2018\\\/06\\\/Monitorizacion-del-sellado-de-bombas-2-jpg.webp\",\"width\":300,\"height\":208,\"caption\":\"Monitorizacion del sellado de bombas (2)\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/monitorizacion-del-sellado-de-bombas-y-depositos-2\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Monitorizaci\u00f3n del sellado de bombas y dep\u00f3sitos\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/#website\",\"url\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/\",\"name\":\"Tecnolog\u00eda para la Industria\",\"description\":\"Soluciones tecnol\u00f3gicas para plantas industriales\",\"publisher\":{\"@id\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pt-PT\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/#organization\",\"name\":\"TPI - Tecnolog\u00eda para la Industria\",\"url\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-PT\",\"@id\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/wp-content\\\/uploads\\\/2020\\\/08\\\/cropped-LOGO-FONDO-BLANCO.png\",\"contentUrl\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/wp-content\\\/uploads\\\/2020\\\/08\\\/cropped-LOGO-FONDO-BLANCO.png\",\"width\":520,\"height\":289,\"caption\":\"TPI - Tecnolog\u00eda para la Industria\"},\"image\":{\"@id\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/tecnologiaparalaindustria\",\"https:\\\/\\\/www.instagram.com\\\/tecnologiaparalaindustria\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/#\\\/schema\\\/person\\\/d04140bd22bb08f9a61cd720e5fe5038\",\"name\":\"REDACCI\u00d3N\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-PT\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/daafa31e3c3038855edc007ca2e41a7f1af1259b6b79b93359d6de82934c5943?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/daafa31e3c3038855edc007ca2e41a7f1af1259b6b79b93359d6de82934c5943?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/daafa31e3c3038855edc007ca2e41a7f1af1259b6b79b93359d6de82934c5943?s=96&d=mm&r=g\",\"caption\":\"REDACCI\u00d3N\"},\"sameAs\":[\"https:\\\/\\\/tecnologiaparalaindustria.com\\\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Controlo da estanquidade de bombas e reservat\u00f3rios","description":"La monitorizaci\u00f3n del sellado de bombas vigila la tasa de cambio en el nivel de medida del flujo de los sellos de la bomba para alertar mantenimiento.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/tecnologiaparalaindustria.com\/pt\/monitorizacion-del-sellado-de-bombas-y-depositos-2\/","og_locale":"pt_PT","og_type":"article","og_title":"Monitorizaci\u00f3n del sellado de bombas y dep\u00f3sitos","og_description":"La monitorizaci\u00f3n del sellado de bombas vigila la tasa de cambio en el nivel de medida del flujo de los sellos de la bomba para alertar mantenimiento.","og_url":"https:\/\/tecnologiaparalaindustria.com\/pt\/monitorizacion-del-sellado-de-bombas-y-depositos-2\/","og_site_name":"Tecnolog\u00eda para la Industria","article_publisher":"https:\/\/www.facebook.com\/tecnologiaparalaindustria","article_published_time":"2018-06-13T09:00:23+00:00","article_modified_time":"2025-07-22T11:58:27+00:00","og_image":[{"width":300,"height":208,"url":"https:\/\/tecnologiaparalaindustria.com\/wp-content\/uploads\/2018\/06\/Monitorizacion-del-sellado-de-bombas-2-jpg.webp","type":"image\/jpeg"}],"author":"REDACCI\u00d3N","twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"REDACCI\u00d3N","Tempo estimado de leitura":"6 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/tecnologiaparalaindustria.com\/monitorizacion-del-sellado-de-bombas-y-depositos-2\/#article","isPartOf":{"@id":"https:\/\/tecnologiaparalaindustria.com\/monitorizacion-del-sellado-de-bombas-y-depositos-2\/"},"author":{"name":"REDACCI\u00d3N","@id":"https:\/\/tecnologiaparalaindustria.com\/#\/schema\/person\/d04140bd22bb08f9a61cd720e5fe5038"},"headline":"Monitorizaci\u00f3n del sellado de bombas y dep\u00f3sitos","datePublished":"2018-06-13T09:00:23+00:00","dateModified":"2025-07-22T11:58:27+00:00","mainEntityOfPage":{"@id":"https:\/\/tecnologiaparalaindustria.com\/monitorizacion-del-sellado-de-bombas-y-depositos-2\/"},"wordCount":1206,"commentCount":0,"publisher":{"@id":"https:\/\/tecnologiaparalaindustria.com\/#organization"},"image":{"@id":"https:\/\/tecnologiaparalaindustria.com\/monitorizacion-del-sellado-de-bombas-y-depositos-2\/#primaryimage"},"thumbnailUrl":"https:\/\/tecnologiaparalaindustria.com\/wp-content\/uploads\/2018\/06\/Monitorizacion-del-sellado-de-bombas-2-jpg.webp","keywords":["Art\u00edculos"],"articleSection":["Automatizaci\u00f3n y control"],"inLanguage":"pt-PT","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/tecnologiaparalaindustria.com\/monitorizacion-del-sellado-de-bombas-y-depositos-2\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/tecnologiaparalaindustria.com\/monitorizacion-del-sellado-de-bombas-y-depositos-2\/","url":"https:\/\/tecnologiaparalaindustria.com\/monitorizacion-del-sellado-de-bombas-y-depositos-2\/","name":"Controlo da estanquidade de bombas e reservat\u00f3rios","isPartOf":{"@id":"https:\/\/tecnologiaparalaindustria.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/tecnologiaparalaindustria.com\/monitorizacion-del-sellado-de-bombas-y-depositos-2\/#primaryimage"},"image":{"@id":"https:\/\/tecnologiaparalaindustria.com\/monitorizacion-del-sellado-de-bombas-y-depositos-2\/#primaryimage"},"thumbnailUrl":"https:\/\/tecnologiaparalaindustria.com\/wp-content\/uploads\/2018\/06\/Monitorizacion-del-sellado-de-bombas-2-jpg.webp","datePublished":"2018-06-13T09:00:23+00:00","dateModified":"2025-07-22T11:58:27+00:00","description":"La monitorizaci\u00f3n del sellado de bombas vigila la tasa de cambio en el nivel de medida del flujo de los sellos de la bomba para alertar mantenimiento.","breadcrumb":{"@id":"https:\/\/tecnologiaparalaindustria.com\/monitorizacion-del-sellado-de-bombas-y-depositos-2\/#breadcrumb"},"inLanguage":"pt-PT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/tecnologiaparalaindustria.com\/monitorizacion-del-sellado-de-bombas-y-depositos-2\/"]}]},{"@type":"ImageObject","inLanguage":"pt-PT","@id":"https:\/\/tecnologiaparalaindustria.com\/monitorizacion-del-sellado-de-bombas-y-depositos-2\/#primaryimage","url":"https:\/\/tecnologiaparalaindustria.com\/wp-content\/uploads\/2018\/06\/Monitorizacion-del-sellado-de-bombas-2-jpg.webp","contentUrl":"https:\/\/tecnologiaparalaindustria.com\/wp-content\/uploads\/2018\/06\/Monitorizacion-del-sellado-de-bombas-2-jpg.webp","width":300,"height":208,"caption":"Monitorizacion del sellado de bombas (2)"},{"@type":"BreadcrumbList","@id":"https:\/\/tecnologiaparalaindustria.com\/monitorizacion-del-sellado-de-bombas-y-depositos-2\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/tecnologiaparalaindustria.com\/"},{"@type":"ListItem","position":2,"name":"Monitorizaci\u00f3n del sellado de bombas y dep\u00f3sitos"}]},{"@type":"WebSite","@id":"https:\/\/tecnologiaparalaindustria.com\/#website","url":"https:\/\/tecnologiaparalaindustria.com\/","name":"Tecnologia para a ind\u00fastria","description":"Solu\u00e7\u00f5es tecnol\u00f3gicas para instala\u00e7\u00f5es industriais","publisher":{"@id":"https:\/\/tecnologiaparalaindustria.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/tecnologiaparalaindustria.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pt-PT"},{"@type":"Organization","@id":"https:\/\/tecnologiaparalaindustria.com\/#organization","name":"TPI - Tecnologia para a Ind\u00fastria","url":"https:\/\/tecnologiaparalaindustria.com\/","logo":{"@type":"ImageObject","inLanguage":"pt-PT","@id":"https:\/\/tecnologiaparalaindustria.com\/#\/schema\/logo\/image\/","url":"https:\/\/tecnologiaparalaindustria.com\/wp-content\/uploads\/2020\/08\/cropped-LOGO-FONDO-BLANCO.png","contentUrl":"https:\/\/tecnologiaparalaindustria.com\/wp-content\/uploads\/2020\/08\/cropped-LOGO-FONDO-BLANCO.png","width":520,"height":289,"caption":"TPI - Tecnolog\u00eda para la Industria"},"image":{"@id":"https:\/\/tecnologiaparalaindustria.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/tecnologiaparalaindustria","https:\/\/www.instagram.com\/tecnologiaparalaindustria\/"]},{"@type":"Person","@id":"https:\/\/tecnologiaparalaindustria.com\/#\/schema\/person\/d04140bd22bb08f9a61cd720e5fe5038","name":"EDITORIAL","image":{"@type":"ImageObject","inLanguage":"pt-PT","@id":"https:\/\/secure.gravatar.com\/avatar\/daafa31e3c3038855edc007ca2e41a7f1af1259b6b79b93359d6de82934c5943?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/daafa31e3c3038855edc007ca2e41a7f1af1259b6b79b93359d6de82934c5943?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/daafa31e3c3038855edc007ca2e41a7f1af1259b6b79b93359d6de82934c5943?s=96&d=mm&r=g","caption":"REDACCI\u00d3N"},"sameAs":["https:\/\/tecnologiaparalaindustria.com\/"]}]}},"featured_image_src":"https:\/\/tecnologiaparalaindustria.com\/wp-content\/uploads\/2018\/06\/Monitorizacion-del-sellado-de-bombas-2-jpg.webp","featured_image_src_square":"https:\/\/tecnologiaparalaindustria.com\/wp-content\/uploads\/2018\/06\/Monitorizacion-del-sellado-de-bombas-2-jpg.webp","author_info":{"display_name":"REDACCI\u00d3N","author_link":"https:\/\/tecnologiaparalaindustria.com\/pt\/author\/tecnologiavao\/"},"acf":[],"_links":{"self":[{"href":"https:\/\/tecnologiaparalaindustria.com\/pt\/wp-json\/wp\/v2\/posts\/1523","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tecnologiaparalaindustria.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/tecnologiaparalaindustria.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/tecnologiaparalaindustria.com\/pt\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/tecnologiaparalaindustria.com\/pt\/wp-json\/wp\/v2\/comments?post=1523"}],"version-history":[{"count":0,"href":"https:\/\/tecnologiaparalaindustria.com\/pt\/wp-json\/wp\/v2\/posts\/1523\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tecnologiaparalaindustria.com\/pt\/wp-json\/wp\/v2\/media\/1529"}],"wp:attachment":[{"href":"https:\/\/tecnologiaparalaindustria.com\/pt\/wp-json\/wp\/v2\/media?parent=1523"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/tecnologiaparalaindustria.com\/pt\/wp-json\/wp\/v2\/categories?post=1523"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/tecnologiaparalaindustria.com\/pt\/wp-json\/wp\/v2\/tags?post=1523"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}